Protein Science
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print December 1, 2005, 10.1110/ps.051734306
Protein Science (2006), 15:45-57. Published by Cold Spring Harbor Laboratory Press. Copyright © 2006 The Protein Society
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
ps.051734306v1
15/1/45    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cannon, M. B.
Right arrow Articles by Remington, S. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cannon, M. B.
Right arrow Articles by Remington, S. J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Re-engineering redox-sensitive green fluorescent protein for improved response rate

Mark B. Cannon1 and S. James Remington2

1 Department of Chemistry and 2 Department of Physics, Institute of Molecular Biology, University of Oregon, Eugene, Oregon 97403-1229, USA

(RECEIVED July 27, 2005; FINAL REVISION September 27, 2005; ACCEPTED September 29, 2005)

Redox-sensitive variants of the green fluorescent protein (roGFPs) had previously been developed that allow "real-time" monitoring of the redox status of cellular compartments by fluorescence excitation ratiometry. However, the response time of these probes limits the study of certain rapid oxidative events, such as H2O2 bursts in cell signaling. The substitution of up to three positively charged amino acids adjacent to the introduced disulfide in roGFP1 (variants designated roGFP1-R1 through -R14) substantially improved the response rate. The pseudo first-order rate constants for oxidation by H2O2 and reduction by DTT and redox midpoint potentials were determined. The rate constants approximately doubled with each additional positively charged substitution, to nearly an order of magnitude total. The midpoint potentials are highly correlated with the rate increases, becoming more oxidizing with increasing numbers of positive substitutions. Crystal structures of two variants with opposite disulfide oxidation states have been determined: a 2.2 Å resolution structure of oxidized "R7" containing two basic substitutions, and a 1.95 Å resolution structure of reduced "R8" with one basic and one acidic substitution. Nonlinear Poisson-Boltzmann (PB) calculations are shown to accurately predict the effects of the substitutions on the rate constants. The effects of the substitutions on dimer formation, relative oxidative midpoint potentials, and oxidation and reduction rates are discussed. roGFPs are demonstrated to constitute an excellent model system for quantitative analysis of factors influencing thiol transfer reactions. roGFP1-R12 is most suitable for use in live cells, due to significantly increased reaction rate and increased pI.

Keywords: roGFP; redox; biosensor; disulfide conformation; midpoint potential; active-site design; rate enhancement; electrostatics calculation

Abbreviations: GFP, green fluorescent protein • roGFP, redox-sensitive GFP • rxYFP, redox-sensitive yellow fluorescent protein • DTT, dithiothreitol • GSH, glutathione • GSSG, glutathione disulfide

Article published online ahead of print. Article and publication date are at http://www.proteinscience.org/cgi/doi/10.1110/ps.051734306.


Reprint requests to: S. James Remington, Department of Physics, Institute of Molecular Biology, University of Oregon, Eugene, OR 97403-1229, USA; e-mail: jremington{at}uoxray.uoregon.edu; fax: (541) 346-5870.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Exp. Biol. Med.Home page
V. L. Kolossov, B. Q. Spring, A. Sokolowski, J. E. Conour, R. M. Clegg, P. J. A. Kenis, and H. R. Gaskins
Engineering Redox-Sensitive Linkers for Genetically Encoded FRET-Based Biosensors
Experimental Biology and Medicine, February 1, 2008; 233(2): 238 - 248.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by The Protein Society.