Protein Science
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by LIU, M.
Right arrow Articles by GIDDINGS, J. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by LIU, M.
Right arrow Articles by GIDDINGS, J. C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Protein Science, Vol 2, Issue 9 1520-1531, Copyright © 1993 by Cold Spring Harbor Laboratory Press


ARTICLE

Rapid protein separation and diffusion coefficient measurement by frit inlet flow field-flow fractionation

M. LIU, P. LI and J. C. GIDDINGS
Field-Flow Fractionation Research Center, Department of Chemistry, University of Utah, Salt Lake City, Utah 84112

In this study three flow field-flow fractionation (flow FFF) channels are utilized for the separation of proteins and for the simultaneous measurement of their translational diffusion coefficients, D. One channel has a traditional sample inlet, whereas the other two incorporate a frit inlet design that permits more convenient and rapid sample introduction. The dependence of retention time on D, which leads to differential elution and the opportunity to measure D for protein peaks purified by the flow FFF process, is described theoretically and examined experimentally. Factors affecting band broadening, resolution, and optimization are also examined. The separation of proteins is achieved in the time range 4-20 min. Partial resolution is achieved in multiple runs requiring 2 min each. Values of D calculated from retention times are reported for 15 proteins. These include two protein dimers (bovine serum albumin and {gamma}-globulin) not ordinarily accessible to measurement. The D values from the three channels are compared with one another and with literature data. Reasonable consistency (within 3-4%) is found. High-speed repetitive runs can be used to acquire multiple values of D in time intervals as short as 1 min.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Biophys. JHome page
J. V. Nauman, P. G. Campbell, F. Lanni, and J. L. Anderson
Diffusion of Insulin-Like Growth Factor-I and Ribonuclease through Fibrin Gels
Biophys. J., June 15, 2007; 92(12): 4444 - 4450.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by The Protein Society.